Product
     
 
RELIABILITY AND QUALITY IN POWER GENERATION
The growing strength of the Mitsubishi Brand name: MITSUBISHI MGS SERIES DIESEL GENERATOR SET I' The core of the MGS Gen Set is now -5 typed diesel engines for MGS Power Rating
MITSUBISHI DIESEL ENGINES
Ranging in capacity from 0.5 to 56,400 horsepower, Mitsubishi brand diesel engines offer a series of versatile power generating systems. Mitsubishi Heavy Industries, Ltd.
has continually introduced upgraded its engine products since the inception of business in 1917, and now the MITSUBISHI MGS SERIES DIESEL GENERATOR SET provides a higher generating power rating and more advanced control systems than ever before, with proven reliability based on the continued research and development.

The best performance-matched engine system configured with Mitsubishi diesel engines and Mitsubishi turbochargers, which are engineered and manufactured in the same facility, is certain to result in the high productivity and improved fuel economy in the MGS Power Generation.Every unit is inspected and tested before leaving the factory and the test report is sent with the Gen Set. MITSUBISHI MGS - All Mitsubishi assembled, tested and supported.

 
DEPENDABILITY & DURABILITY IN POWER GENERATION
The best performance-matched engine and generator systems give world-class performance I Response and stability designed to exceed user expectations in a variety of applications
AC GENERATOR
4 pole, screen protected, drip-proof IP23, self-exciting, self-regulating and brush less with fully connected damper windings, salient pole rotors, A.C. exciter and rotating rectifier unit. The insulation system is Class 'H'. All windings are impregnated in either a triple dip thermo-setting moisture, oil and acid resisting polyester varnish or vacuum pressure impregnated with a special polyester resin. Electrical design in accordance with BS5000 Part 3, VDE0530, UTE511 00, NEMA MG1-32, CEMA, IEC34-1, CSA22.2 and AS1359.
6 and 12 wire 0' reconnectable windings provide a wide range of 3 phase voltage. The exciter field system remains at full strength, sustaining a high level of short circuit current at the ac generator output terminals by means of the excitation voltage via AVR powered by the independent winding, Permanent Magnet Generator (PM G) as a standard feature in the MGS Gen Set, which is electrically isolated from the main alternator stator windings.
The fully sealed, three phaseo' RMS voltage sensing AVR maintains the voltage within the limits of +/_0.5%03 from no load to full load including cold to hot variations at any power factor between 0.8 lagging and unity allowing for a 4% engine speed variation, suitable for applications with greatly unbalanced or high non-linear loads associated with UPS systems. The AVR has built-in protection against sustained over-excitation, caused by internal or external faults. This de-excites the generator after a minimum of five seconds. THF (as defined by BS4999 Part 40) is better than 2 % and a TIF (as defined by ASA C50.12) is better than 50. Radio interface: Suppression is in line with the provision of BS800 and VDE Class G and N. .
Note: *1 12 wire reconnectable windings are the features up to Code H6 models.     
'2. 3 Up to Code K5 models have single phase voltage sensingand the voltage regulation within +/-1.0%, for 4% engine speed variation.
Turbo-filter is standard and paper element dry type air-cleaner is available as an option
meeting ur needs with wide range and options to assure successful application
MGS SERIES GEN SET RATING
50 Hz , 1500 rpm, With Fan,415
MGS GEN SET MODEL
ENGINE MODEL
CODE std: 5S-Prime: 5P-
APPROVED RATING
Std-by:(kVA)
Prime(kVA)
MGS2500B
S16R-PTAA2
KT83
2290
2035
MGS2000B
S16R-PTA2-S
KT83
2235
2030
MGS1500B
S16R-PTA-S
7PF
2000
1800
MGS1400B
S12R-PTA2-S
7PD
1600
1450
MGS1200B
S12R-PTA-S
7PD
1500
1362.5
MGS1000B
S12H-PTA-S
7PC
1250
1125
MGS1000B
S12H-PTA-S
H6J
1050
1000
MGS0900B
S12H-PTA-S
H6J
1000
885
MGS0700B
S12A2-PTA2-S
H6H
880
800
MGS0650B
S6R2-PTA-S
H6G
780
700
MGS0500B
S6R-PTA-S
H5F
690
625
MGS0500B
S6A3-PTAA-S
H5E
580
530
MGS0450B
S6A3-PTA-S
H5D
515
480
 
Stand-by: Code: S
Applicable for supplying emergency power at varying load in the event of normal utility power interruption. Fuel stop power in accordance with IS015550, IS03046/1, JISB8002-1, DIN6271 and BS5514.
Overload: not allowed
Prime: Code: P
Applicable for supplying emergency power at varying load in the event of normal utility power interruption. 10% overload is allowed. Fuel stop power in accordance with IS015550, IS03046/1, JISB8002-1, DIN6271 and BS5514.
Overload: 10% allowed
Conditions:
Engine ratings are based on SAE J1349 standard conditions and also apply at IS03046/1, DIN6271 & BS5514 standard conditions.
Fuel rates: based on ASTM 0975, BS2869 and on fuel oil of 35° API (16°C or 60° F) gravity having a LHV of 42,780 kJ/kg (18,390 Btu/lb.) when used at 29°C (85°F) and weighing 838.9 g/liter (7.001 Ibs./U.S. gaL).
 
ADVANCED SOLUTIONS IN POWER GENERATION
"Full- sized" safety and automatic functions in the series of digital control systems Easy human interface in the sophisticated control system makes for an operator-friendly Gen Set
MGS SERIES CONTROL PANEL
MGS standard Microprocessor control- automatic start/stop panel, indication of the operational status and fault conditions; automatically shutting down the engine and indicating the engine failure by means of a graphical LCD display and flashing LED on the front panel. Electrical design in accordance with BS EN 60950 Low Voltage Directive, BS EN 50081-2 and 50082-2 EMC Directive. The optional interface can provide real time diagnostic facilities.
Alarms are indicated by an LCD icon and LED illumination.
 
 
 
back
 
                                                                        
Home | About Us | Products | Feedback | Clients | Contact Us                                         LOGIN